Product Introduction:
The instrument can measure mercury in liquid samples, but also on the treated solid samples into liquid or gaseous mercury is measured in the sample, it can be widely used in environmental monitoring, health care, food inspection, geological exploration and chemical research in areas such as determination of trace mercury analysis.
Scope:
This instrument is suitable for environmental monitoring, health and epidemic prevention, water, chemical and other industries for the measurement of water, air, soil, food, cosmetics, chemical raw materials, the mercury content.
Functions and Features:
This instrument is built-in microcomputer systems, measurement and calculation capabilities significantly enhanced instrument through the LCD screen displays the current status, measurements or other parameters, with the print output, but also with RS-232C serial interface. Instrument is simple to use, stable and reliable. The advantages of measuring fast, simple operation, digital display, direct reading, is the ideal tool for laboratory measurement of mercury.
Technical parameters:
Product Name | Cold vapor atomic absorption mercury analyzer |
Product Type | NB26-VJ |
Measuring range | 0-10μg/L(high-concentration samples can be quantitatively measured after dilution) |
The detection limit | ≤ 0.05μg / L |
Linearity error | ± 10% |
Repeatability | ≤ 3% |
Stability | ± 2 counts / 3 minutes (at A = 0 Office) |
Power supply | AC 220V/50HZ |
Power | 22W |
Weight | 4.6Kg (NW) |
Dimensions(mm3) | 368 × 288 × 158 |
Other types of parameters:
Model | NB26-V | NB26-S | NB-26-G |
Name | intelligent mercury analyzer | double-beam digital display mercury analyzer | single-beam digital display mercury analyzer |
Sensitivity | no less than 0.05mg/l | no less than 0.1mg/l | no less than 0.1mg/l |
Measuring range | 0-10.0 micrograms/ liter (20 mm reduction flask add 5 ml standard sample and 1 ml reducing agent) | 0-10.0 micrograms / liter (20 mm flask add 5 ml restore standard sample and 1 ml reducing agent) | 0-10.0 micrograms / liter (20 mm reduction flask add 5 ml standard sample and 1 ml reducing agent) |
Stability | reading drift ≤ ± 2 words / 3 minutes (at A = 0 Office) | the specified measuring range, reading words drift ≤ ± 2/3 min | the predetermined measuring range, the reading drift ≤ ± 2 words / 1.5 minutes |
Precision | coefficient of variation ≤ 5% |
Power supply voltage | 220 volts |
Instrument Weight | 12 kg | 12 kg | 9 kg |
Dimensions(mm3) | 510 × 330 × 155 | 510 × 300 × 135 | 360 × 310 × 160 |