Hot sale protein measuring machine with nice reputation
Operating system
² Operating system has 7.5 inches large color touch display screen, SIEMENS CPU control platform, and can be connected to wireless mouse.
² It has Chinese display interface with perfect man-machine interaction function, and the operational process is easy to operate and understand
² Two operating modes, automatic analysis and manual analysis, can meet requirements of different experiments.
² USB data communication interface, standard configuration, is convenient for users to inquire raw data.
² Wireless mouse, standard configuration
Executive system
² It adopts self-priming diaphragm pump imported with original packaging from British to feed liquid and thoroughly weeds out pneumatic diaphragm pump used by many domestic factories. Feeding liquid by self-primingpump can put liquid-feeding barrel under the operating floor which has advantages of effectively saving lab room, choosing large capacity liquid-feeding barrel, etc.
Control system
² Main control system adopts advanced PLC control platform: the system control is reliable and accurate.
² Intelligent cooling water automatic switching system: when there is steam, the cooling water turns on automatically; when there is no steam, the cooling water turns off automatically. It can save cooling water to maximum extent and avoid unwanted loss which is caused because operator forgets to turn off water source.
² Pre-heat function: when it is in starting-up or ready mode, the temperature of steam cylinder always keeps 80°C. When measure and analysis are needed, it can produce steam quickly which can shorten waiting time.
² Automatic dilution function to avoid strong acid and alkali overreaction: before adding alkali, right amount of distilled water shall be added to dilute strong acid sample in order to avoid strong reaction when strong acid meets strong alkali.
² Program of automatically washing titration cup: it can avoid non-neutral residual liquid influencing low-content or blank sample to improve system accuracy and reliability.
² Unique automatic discharge and centralized collection function of digestion tube waste: after the completion of titration, the digestion tube waste liquid will be discharged automatically and collected intensively. Automaticity is improved greatly, which reduces workers’ labor intensity, solves the centralized collection and treatment of analysis liquid waste and complies with the management standards of good lab.
² Automatic discharge and centralized collection of titration liquid waste: self-priming pump automatic titration liquid waste discharge device make the waste liquid in titration cup discharge more convenient and thorough and also make the pipeline connection more easy and practical because it has the same collection entrance with waste liquid of digestion tube.
² All pipelines of the instrument adopt imported materials and have sealed structure which could extent the service life of the instrument.
² Automatic calibration system of titration liquid concentration (mol)
² Dual mode of automatic calibration method which instrument eliminates errors and traditional direct input method
² Automatic calibration method which instrument eliminates errors: this method eliminates system errors which are caused by the difference between the exterior calibration of instrument and the instrument titration (calibration) and makes the system precision higher.
Safety protection system
² Digestion tube vacant protection: the system will not heat up if the digestion tube isn’t put in;
² Safety door vacant protection: if the safety door isn’t pull down, the system will not heat up;
² Automatic water-replenishing function of steam cylinder: when the steam generator has no water or its water level not high enough, the system will replenish water automatically to avoid burning without water;
² Steam overpressure protection: when the pressure of steam generator system is too high because of the blocking and breakdown of steam pipeline or abnormal steam pipeline, the system will automatically stop running and give an alarm;
Leakage protection: when system has leakage of electricity or the operator gets an electric shock by accident, the system will switch off the electricity and cut off power supply to make sure the operator is safe.
Technical parameters of JK2000:
1.Range 0 ~250mgN (4 ranges) Minimum Value 0.02mgN
2.Density Accuracy RSD ≤5%
3.Relative Error RE ≤±10%(≤1mg/L NH3-N)
≤±5% (≥1mg/L NH3-N)
4.Measuring Speed ≤10min/sample
5.Data Storage Effective Memory 6G
6.Display 7.2”True Color Touch Screen
7.Operation Temperature10~40°C
8.Operation Humidity Max 80%(relative)
9.Power AC200~240V /50/60HZ
10.Heating Power 120W
parameter of JK9830
automatic Kjeldahl Analyzer
Model | JK9830 |
Measuring range | 0.1-250mgN |
Recovery ratio | no less than 99.5% |
Repeatability precision | ±0.5% |
Weight of measured samples | Solid<6g liquid<16ml |
Distillation speed | 5-8min/sample |
Distillation time | Set it at will |
Cooling water consumption | 1.5L/min |
Operation mode | Auto/manual dual mode |
Display mode | 6 inches LCD |
Power input range | AC 220V |
Max power | 1500W (220V AC 50Hz) |
Automatic control on adding alkali and boric acid, dilution and elution |
parameter of JK9870 series:
Model | JK9870 | JK9870A |
Working process | Adding quantitative sample dilution, alkali liquor and absorption liquid; automatically finishing distillation, titration, print and liquid-discharging. |
Measurement range | 0.1-240mgN |
Measurement sample amount | Solid<6g liquid<16ml |
Measurement time | 4-8 minutes |
Titration precision | 0.5Ul/step |
Titration solution concentration | Direct titration samples with 4 titration concentrations of 0.1mol,0.2mol,0.5 mol and 1 mol |
Titration system | High-precision plunger type titration system | High-precision peristaltic titration system |
Executive standard | Comply with stipulations of AOAC, EPA, DIN, ISO AND GB |
Repeatability precision | ±0.5% |
Recovery ratio | ≥99.5% |
Data storage | Effective storage space 2G |
Print function | 110mm line printer which can realize user selective print function |
Power | 1800w |
Power supply | 220v/50Hz |
Requirement of cooling water | Under 25°C |
Cooling water consumption | 1.5L/min (Distillation process) |